Breather Membranes

What is it? A Breather Membrane is a fire-classified, microporous membrane that provides a vapour- permeable protective layer around buildings. Where is it used? Breather Membranes are secured horizontally or vertically to the sheathing board using double-sided tape, and sealed at joints/ overlaps/edges using UV Facade Tape. Why do we use it? The Breather Membrane provides a weather resistive layer, whilst at the same time, allowing vapour to escape from the cavity, and thus reducing the risk of condensation and vapour build-up.

BREATHER MEMBRANES Harmonised Standard

MIN. REQUIREMENT

OBEX CORTEX 0521FR

OBEX CORTEX 0520FR

OBEX CORTEX 0220FR

OBEX CORTEX 0221FR

OBEX CORTEX 0223FR

STANDARD

EN 13859-2 Compliance

Compliant

Compliant

Compliant

Compliant

Compliant

Fire Classification EN 13501-1 B-s3,d0 minimum B-s1,d0

B-s3,d0

A1

A2-s1,d0

A2-s1,d0

Water Penetration

EN 1928

W1/W2

W1

W1

W2

W2

W1

Airtightness

EN 12114

<0.1m³ leakage

0 m³/h/m²

<0.1m³

84m³

84m³

<0.1m³

Water Vapour Transmission

EN ISO 12572 Set C

<0.12m

0.1m

0.1m

0.03m

0.03m

0.08m

> 100N/50mm (MD, CD)

Tensile Strength EN 12311-2

255 / 180

255 / 180 3828 / 1992 3828 / 1992 2968 / 3253

Tear Strength

EN 12310-2 > 80 N (MD, CD)

100 / 106

100 / 106

356 / 424

356 / 424

577 / 453

Cold Temperature Flexibility

EN 495-5, EN 1109

-40°C

Pass

Pass

Pass

Pass

Pass

UV & Heat Ageing EN 1296/1297 Pass - watertight

Pass

Pass

Pass

Pass

Pass

Service Temperature

-40°C to >+70°C

Yes

Yes

Yes

Yes

Yes

UV resistance

6 months

Yes

Yes

Yes

Yes

Yes

04 | SALES-UK@OBEXGLOBAL.COM | 01905 337 800

What is it? An Interface Sealing Membrane is a fire-classified material that’s bonded to window and façade interfaces to provide a watertight and airtight seal. Where is it used? Using fire-classified Paste Adhesive, Interface Sealing Membranes are used specifically to provide watertight & airtight seal around windows, doors, curtain walling and board/slab-edge interfaces and many other applications Why do we use it? We use Interface Sealing Membranes at these specific locations because they meet the demanding weathering performance requirements at high risk locations, and they also meet the fire classifications required by Regulation 7 and Approved Document B. ISM’s (Interface Sealing Membranes)

What ageing testing is required? 90-day 70°C heat age (EN 1296) – Tested to EN 1931 (WVT) and/or EN 1928 watertightness (2kPa for 24 hours)

OBEX CORTEX 0200FR

OBEX CORTEX 0500FR

OBEX CORTEX 0560FR

OBEX CORTEX EPDM

ISM’S & EPDM STANDARD

MIN. REQUIREMENT

Harmonised Standard

EN 13984

Compliance

Compliant

Compliant

Compliant

Compliant

Class E, combustible

Fire Classification EN 13501-1

B-s3,d0 minimum

A2-s1,d0

B-s3,d0

B-s3,d0

Water Penetration EN 1928

Pass, 2kPa for 24 hours

Pass

Pass

Pass

Pass

Airtightness

EN 12114

<0.1m³ leakage

<0.1m³

<0.1m³

<0.1m³

<0.1m³

Water Vapour Transmission

EN 1931

>5m

>50m

12m

12m

37.5m

Tensile Strength EN 12311-2

> 250N/50mm (MD, CD)

7767 / 3973

2490 / 2079

2490 / 2079

> 7Mpa

Tear Strength

EN 12310-2

> 10 N (MD, CD)

519 / 436

230/230

429/452

10

Cold Temperature Flexibility

EN 495-5, EN 1109

-40°C

Pass

Pass

Pass

Pass

UV & Heat Ageing EN 1296/1297 Pass - watertight

Pass

Pass

Pass

Pass

Service Temperature

-40°C to >+70°C

Yes

Yes

Yes

Yes

Flexibility

Flexible

Yes

Yes

Yes

Yes

Class E, combustible Class E, combustible

Paste adhesive

Class B minimum

Yes, A2-s1,d0

Yes, B-s1,d0

Yes, B-s1,d0

Primer

Class B minimum

Yes, B-s1,d0

Yes, B-s1,d0

Yes, B-s1,d0

Ease of Installation

Good

Very Good

Good

Very Good

Good

OBEXGLOBAL.COM | 05

What is it? A Vapour Control Layer is an air/vapour- tight membrane that is installed internally to increase airtightness, improve moisture management and energy efficiency. VCL (Vapour Control Layer) Where is it used? The VCL is fixed to the internal side of the Steel Framing System using double-sided tape, and sealed at the edges with UV Façade Tape. Why do we use it? A VCL provides an airtight layer which minimises the amount of warm/moist air that enters the fabric of the building and to protect the structure from degradation due to condensation and vapour build up.

OBEX CORTEX 0230FR

OBEX CORTEX 0530FR

VCL’S

STANDARD

MIN. REQUIREMENT

Harmonised Standard

EN 13984

Compliance

Compliant

Compliant

Fire Classification

EN 13501-1

B-s3,d0 minimum

Class A2-s1,d0

B-s1,d0

Water Penetration

EN 1928

Pass, 2kPa for 24 hours

Pass

Pass

Airtightness

EN 12114

<0.1m³ leakage

<0.1m³

0m³/h/m² (+/- 100 Pa)

Water Vapour Transmission EN 1931

>1500m

2575.35m

100m

Vapour resistance

EN 1931

12,874 MNs/g

500 MNs/g

Tensile Strength

EN 12311-2

> 1000/50mm (MD, CD)

1362 / 1349

160 / 155

Tear Strength

EN 12310-2

> 100 N (MD, CD)

150 / 150 N

142 N

Heat Ageing

EN 1296

Pass

Pass

Pass

Service Temperature

-40°C to >+70°C

Yes

Yes

Ease of Installation

Good

Good

Good

06 | SALES-UK@OBEXGLOBAL.COM | 01905 337 800

Sheathing Board

What is it? An external sheathing board is a fire-classified cement-based board which is highly resistant to weathering and provides a surface for mounting items such as breather membranes and facade systems. Where is it used? The sheathing board is usually fixed to the outside of the Steel Framing System using self-drilling screws. Why do we use it? A sheathing board is installed onto the SFS frame to make a building weather-tight as quickly as possible so that internal trades can start earlier in the construction process. Sheathing boards also provide thermal, acoustic and fire resistance properties which contribute to the performance of the building.

MIN. REQUIREMENT

OBEX CORTEX 0270FR

SHEATHING BOARD

STANDARD

Harmonised Standard

EN 12467

Category B

Category B - pass

Fire Classification

EN 13501-1

A2-s1,d0 minimum

Class A1

Modulus of Rupture

EN 12467

Class 1

Class 1

Water Impermeability

EN 12467

No drops

Pass, no drops

Durability - Freeze-thaw

EN 12467

Pass

Pass

Durability - Heat-rain

EN 12467

Pass

Pass

Durability - Warm water

EN 12467

Pass

Pass

Durability - Soak-dry

EN 12467

Pass

Pass

Density

EN 12467

≥625kg/m³

1000kg/m³

Weight

Less than 40kg

36kg

Health & Safety

Good

Excellent

Ease of Installation

Good

Excellent

OBEXGLOBAL.COM | 7