What is it? An Interface Sealing Membrane is a fire-classified material that’s bonded to window and façade interfaces to provide a watertight and airtight seal. Where is it used? Using fire-classified Paste Adhesive, Interface Sealing Membranes are used specifically to provide watertight & airtight seal around windows, doors, curtain walling and board/slab-edge interfaces and many other applications Why do we use it? We use Interface Sealing Membranes at these specific locations because they meet the demanding weathering performance requirements at high risk locations, and they also meet the fire classifications required by Regulation 7 and Approved Document B. ISM’s (Interface Sealing Membranes)
What ageing testing is required? 90-day 70°C heat age (EN 1296) – Tested to EN 1931 (WVT) and/or EN 1928 watertightness (2kPa for 24 hours)
OBEX CORTEX 0200FR
OBEX CORTEX 0500FR
OBEX CORTEX 0560FR
OBEX CORTEX EPDM
ISM’S & EPDM STANDARD
MIN. REQUIREMENT
Harmonised Standard
EN 13984
Compliance
Compliant
Compliant
Compliant
Compliant
Class E, combustible
Fire Classification EN 13501-1
B-s3,d0 minimum
A2-s1,d0
B-s3,d0
B-s3,d0
Water Penetration EN 1928
Pass, 2kPa for 24 hours
Pass
Pass
Pass
Pass
Airtightness
EN 12114
<0.1m³ leakage
<0.1m³
<0.1m³
<0.1m³
<0.1m³
Water Vapour Transmission
EN 1931
>5m
>50m
12m
12m
37.5m
Tensile Strength EN 12311-2
> 250N/50mm (MD, CD)
7767 / 3973
2490 / 2079
2490 / 2079
> 7Mpa
Tear Strength
EN 12310-2
> 10 N (MD, CD)
519 / 436
230/230
429/452
10
Cold Temperature Flexibility
EN 495-5, EN 1109
-40°C
Pass
Pass
Pass
Pass
UV & Heat Ageing EN 1296/1297 Pass - watertight
Pass
Pass
Pass
Pass
Service Temperature
-40°C to >+70°C
Yes
Yes
Yes
Yes
Flexibility
Flexible
Yes
Yes
Yes
Yes
Class E, combustible Class E, combustible
Paste adhesive
Class B minimum
Yes, A2-s1,d0
Yes, B-s1,d0
Yes, B-s1,d0
Primer
Class B minimum
Yes, B-s1,d0
Yes, B-s1,d0
Yes, B-s1,d0
Ease of Installation
Good
Very Good
Good
Very Good
Good
OBEXGLOBAL.COM | 05