OBEX - Façade Elements of The Through-Wall Construction

Breather Membranes

What is it? A Breather Membrane is a fire-classified, microporous membrane that provides a vapour- permeable protective layer around buildings. Where is it used? Breather Membranes are secured horizontally or vertically to the sheathing board using double-sided tape, and sealed at joints/ overlaps/edges using UV Facade Tape. Why do we use it? The Breather Membrane provides a weather resistive layer, whilst at the same time, allowing vapour to escape from the cavity, and thus reducing the risk of condensation and vapour build-up.

BREATHER MEMBRANES Harmonised Standard

MIN. REQUIREMENT

OBEX CORTEX 0521FR

OBEX CORTEX 0520FR

OBEX CORTEX 0220FR

OBEX CORTEX 0221FR

OBEX CORTEX 0223FR

STANDARD

EN 13859-2 Compliance

Compliant

Compliant

Compliant

Compliant

Compliant

Fire Classification EN 13501-1 B-s3,d0 minimum B-s1,d0

B-s3,d0

A1

A2-s1,d0

A2-s1,d0

Water Penetration

EN 1928

W1/W2

W1

W1

W2

W2

W1

Airtightness

EN 12114

<0.1m³ leakage

0 m³/h/m²

<0.1m³

84m³

84m³

<0.1m³

Water Vapour Transmission

EN ISO 12572 Set C

<0.12m

0.1m

0.1m

0.03m

0.03m

0.08m

> 100N/50mm (MD, CD)

Tensile Strength EN 12311-2

255 / 180

255 / 180 3828 / 1992 3828 / 1992 2968 / 3253

Tear Strength

EN 12310-2 > 80 N (MD, CD)

100 / 106

100 / 106

356 / 424

356 / 424

577 / 453

Cold Temperature Flexibility

EN 495-5, EN 1109

-40°C

Pass

Pass

Pass

Pass

Pass

UV & Heat Ageing EN 1296/1297 Pass - watertight

Pass

Pass

Pass

Pass

Pass

Service Temperature

-40°C to >+70°C

Yes

Yes

Yes

Yes

Yes

UV resistance

6 months

Yes

Yes

Yes

Yes

Yes

04 | SALES-UK@OBEXGLOBAL.COM | 01905 337 800