OBEX - Façade Elements of The Through-Wall Construction

Sheathing Board

What is it? An external sheathing board is a fire-classified cement-based board which is highly resistant to weathering and provides a surface for mounting items such as breather membranes and facade systems. Where is it used? The sheathing board is usually fixed to the outside of the Steel Framing System using self-drilling screws. Why do we use it? A sheathing board is installed onto the SFS frame to make a building weather-tight as quickly as possible so that internal trades can start earlier in the construction process. Sheathing boards also provide thermal, acoustic and fire resistance properties which contribute to the performance of the building.

MIN. REQUIREMENT

OBEX CORTEX 0270FR

SHEATHING BOARD

STANDARD

Harmonised Standard

EN 12467

Category B

Category B - pass

Fire Classification

EN 13501-1

A2-s1,d0 minimum

Class A1

Modulus of Rupture

EN 12467

Class 1

Class 1

Water Impermeability

EN 12467

No drops

Pass, no drops

Durability - Freeze-thaw

EN 12467

Pass

Pass

Durability - Heat-rain

EN 12467

Pass

Pass

Durability - Warm water

EN 12467

Pass

Pass

Durability - Soak-dry

EN 12467

Pass

Pass

Density

EN 12467

≥625kg/m³

1000kg/m³

Weight

Less than 40kg

36kg

Health & Safety

Good

Excellent

Ease of Installation

Good

Excellent

OBEXGLOBAL.COM | 7