OBEX - Façade Elements of The Through-Wall Construction

What is it? An Air & Vapour Control Layer is an air/ vapour-tight membrane that is installed internally to increase airtightness, improve moisture management and energy efficiency. Where is it used? The AVCL is fixed to the internal side of the Steel Framing System using double-sided tape, and sealed at the edges with UV Façade Tape. Why do we use it? An AVCL provides an airtight layer which minimises the amount of warm/moist air that enters the fabric of the building and to protect the structure from degradation due to condensation and vapour build up. AVCL (Air & Vapour Control Layer)

OBEX CORTEX 0230FR

OBEX CORTEX 0530FR

OBEX CORTEX 0531FR

VCL’S

STANDARD

MIN. REQUIREMENT

Harmonised Standard EN 13984

Compliance

Compliant

Compliant

Compliant

Fire Classification

EN 13501-1

B-s3,d0 minimum

Class A2-s1,d0

B-s1,d0

B-s1,d0

Pass, 2kPa for 24 hours

Water Penetration

EN 1928

Pass

Pass

Pass

0m³/h/m² (+/- 100 Pa)

0m³/h/m² (+/- 100 Pa)

Airtightness

EN 12114

<0.1m³ leakage

<0.1m³

Water Vapour Transmission (Sd Value) Water Vapour Transmission (MNs/g)

EN 1931

>1500m

2575.35m

100m

100m

EN 1931

12,874 MNs/g

500 MNs/g

500 MNs/g

> 1000/50mm (MD, CD)

Tensile Strength

EN 12311-2

1362 / 1349

160 / 155

130 / 140

Tear Strength

EN 12310-2

> 100 N (MD, CD)

150N

142N

142N

Heat Ageing

EN 1296

Pass

Pass

Pass

Pass

Service Temperature

-40°C to >+70°C

Yes

Yes

Yes

Ease of Installation

Good

Good

Good

Excellent

CE/UKCA Marking

UKCA/CE

UKCA/CE

06 | SALES-UK@OBEXGLOBAL.COM | 01905 337 800