OBEX - Façade Elements of The Through-Wall Construction

What is it? A Vapour Control Layer is an air/vapour- tight membrane that is installed internally to increase airtightness, improve moisture management and energy efficiency. VCL (Vapour Control Layer) Where is it used? The VCL is fixed to the internal side of the Steel Framing System using double-sided tape, and sealed at the edges with UV Façade Tape. Why do we use it? A VCL provides an airtight layer which minimises the amount of warm/moist air that enters the fabric of the building and to protect the structure from degradation due to condensation and vapour build up.

OBEX CORTEX 0230FR

OBEX CORTEX 0530FR

VCL’S

STANDARD

MIN. REQUIREMENT

Harmonised Standard

EN 13984

Compliance

Compliant

Compliant

Fire Classification

EN 13501-1

B-s3,d0 minimum

Class A2-s1,d0

B-s1,d0

Water Penetration

EN 1928

Pass, 2kPa for 24 hours

Pass

Pass

Airtightness

EN 12114

<0.1m³ leakage

<0.1m³

0m³/h/m² (+/- 100 Pa)

Water Vapour Transmission EN 1931

>1500m

2575.35m

100m

Vapour resistance

EN 1931

12,874 MNs/g

500 MNs/g

Tensile Strength

EN 12311-2

> 1000/50mm (MD, CD)

1362 / 1349

160 / 155

Tear Strength

EN 12310-2

> 100 N (MD, CD)

150 / 150 N

142 N

Heat Ageing

EN 1296

Pass

Pass

Pass

Service Temperature

-40°C to >+70°C

Yes

Yes

Ease of Installation

Good

Good

Good

06 | SALES-UK@OBEXGLOBAL.COM | 01905 337 800