FIS-BP-Guide-Through-Wall-SFS

APPENDIX A

OTHER RELEVANT STANDARDS FOR THROUGH-WALL BS EN 10346:2015 Continuously hot dip coated steel flat products for cold forming. Technical delivery conditions

e) Wall and ceiling coverings with fire protection ability f) Lift landing doors tested according to EN 81-58 are excluded from this European Standard. Lift landing doors tested in accordance with EN 1634-1 are classified in accordance with 7.5.5. Relevant test methods that have been prepared for these elements are listed in Clauses 2 and 7. BS EN 1364-1 FIRE RESISTANCE TESTS FOR NON- LOADBEARING ELEMENTS. WALLS BS EN 1365-1 FIRE RESISTANCE TESTS FOR LOADBEARING ELEMENTS. WALLS Note: the above tests do not test the reaction to fire; this is covered by BS EN 13501-1. See Table 4 for the requirements. These tests are devised to test the integrity (E), insulation (I) and, if specified, loadbearing capacity (R) of the tested through-wall. Field of application from fire tests, for example, test smallest stud size and minimal insulation to provide the widest scope for the field of application. TECHNICAL GUIDANCE NOTE 18 USE OF COMBUSTIBLE CLADDING MATERIALS ON BUILDINGS EXCEEDING 18M IN HEIGHT. BCA (BUILDING CONTROL ALLIANCE) ISSUE 1 JUN 2015 Where a building has a storey that is 18m or more above ground level, AD B recommends (for the entire wall area both below and above 18m) either the use of materials of limited combustibility for all key components or to submit evidence that the complete proposed external cladding system has been assessed according to the acceptance criteria in BR 135 Fire Performance of external thermal insulation for walls of multistorey buildings. This guid-ance note outlines both procedures in more detail and addresses common misconceptions relating to combustibil¬ity and surface spreads of flame ratings.

BS EN 1993-1-3:2006 Eurocode 3. Design of steel structures. General rules. Supplementary rules for cold-formed members and sheeting

BS EN 1991-1-4:2005+A1:2010 Eurocode 1. Actions on structures. General actions. Wind actions

BS EN 13501-2:2016 This European Standard specifies the procedure for classification of construction products and building elements using data from fire resistance and smoke leakage tests that are within the direct field of application of the relevant test method. Classification on the basis of extended application of test results is also included in the scope of this European Standard. This European Standard deals with: a) Loadbearing elements without a fire separating function – walls; floors; roofs; beams; columns; balconies; walkways; stairs b) Loadbearing elements with a fire separating function, with or without glazing, services and fixtures – walls; floors; roofs; raised floors c) Products and systems for protecting elements or parts of the works – ceilings with no independent fire resistance; fire protective coatings, claddings and screens d) Non-loadbearing elements or parts of works, with or without glazing, services and fixtures – partitions; façades (curtain walls) and external walls; ceilings with independent fire resistance; raised floors; fire doors and shutters and their closing devices; smoke control doors; conveyor systems and their closures; penetration seals; linear gap seals; service ducts and shafts; chimneys

BS 8414 LARGE SCALE FIRE TESTING BS 8414 is a large-scale system test that mimics a fire breaking out of a window and exposing a cladding system to a severe fire.

37

Powered by