FIS-BP-Guide-Through-Wall-SFS

DESIGN PROCESS

FAÇADE SYSTEMS The choice and specification of façade system will impact the detailing of the through-wall system and should be designed with the manufacturers of the through-wall and cladding systems to ensure they will work together. Façade systems include : • Rainscreen cladding • Composite panel • Brick cladding • Brick slip • Insulated render • Timber cladding • Render on cementitious board. Note: cavity barriers should be considered as part of a system. Note: there are different requirements for cavity barriers for each of the devolved nations. The SFS infill walling forms a secondary structure that is fixed between the primary superstructure at floor and soffit. It is generally positioned at the slab edge, allowing insulation and external finishes to be installed continuously outside the main structural frame.

Though-wall during construction

Infill system

Ventilated rainscreen. Cavity barriers removed for clarity but would be required.

Images: sigmat.co.uk/building-products/sigmat-sfs/

Plasterboard

Studs

Sheathing board

Mineral wool insulation

Helping hand brackets

Jamb stud

Stone mineral wool insulation

Cill track

Façade finish

Slotted head track

Rail system

21